View Single Post
Old 2009-09-30, 18:31   #41
nissen29
 
nissen29's Avatar
 
Statusas: MB1 Forumo Rėmėjas
Užsiregistravo: 2009-07-06
Gyvenamoji Vieta: Klaipėda-Vilnius
Pranešimai: 2,502

nissen29 is on a distinguished road



Standartinis

taigi jau buvo kalbeta apie diagnostikos galimybes, Cukierka rase , va jums kopija:

jei idomu apie klima tai cia ir ka visi skaiciukaj reiskia. tereik uzkurus masina paspaust "rest" ir laikyt kol pasikeis is temperaturos skaiciu i kodus (kairej) ir reiksmes (desinej). o kodai va ka reiskia:

1 temperature of air in the salon, supplied with fan (Vy0/ya).
2 temperatures of air-in (Vyya).
3 temperatures of heat exchanger to the left (Vy0/y).
4 temperatures of heat exchanger to the right (Vy0/y).
5 temperature of vaporizer (Vy0/'). ? *
6 temperature of engine (B11/4).
7 pressure of Freon (Vy2), (for an example of 4 bars).
8 temperature of Freon (Vy2/y), (for an example 23 * s). It is not always completed.
9 it is reserved.
10 control voltage on the regulator of fan, (from 0.8 to 6.0 V).
11 sensor of the presence of harmful substances (Vey), (for example to 3.1 V).
12 sun sensor (Ve2), (for example to 4.2 V).
20 the control current of additional fan, (for example 7 mA).
21 engine speeds X of nay00 r/min.
22 speed of motion, (for an example 55 km/h).
23 brightness of illumination (58d) in %.
24 voltage of storage battery, (for example to 12.8 V).
40 state of software, (for example 37).
41 states of software, (for example 08). ? * If the temperature of sensor high and does not fall with

o cia kaip ijungti klimos diagnostika ir ka kas reiskia:

Ignition. VKL of the button of the installation of temperature, to advance to the left HI, to the right LO. During 20 s, to simultaneously harvest buttons REST and EC to hold pressed 5 s. Button "internal circulation" blinks (1 Hz). Button AUTO press there will thus far not be schitany all malfunctions. The code (cm table) is appropriated to each malfunction, it is mapped onto display from both sides. The codes are discarded with the simultaneous pushing of knobs AUTO, 2 s, ignition OF THE OFF, the end diagnostic routine.
N22 Indication of the malfunction Malfunction in the system is not discovered.
B1226 The temperature sensor of air in the salon, supplied with fan (B10/4).
B1227 The temperature sensor of surrounding air (B14).
B1228 The temperature sensor of heat exchanger to the left (B10/1).
B1229 The temperature sensor of heat exchanger to the right (Vy0/y).
B1230 The temperature sensor of vaporizer (Vy0/').
B1231 The temperature sensor of engine (B11/4).
B1232 The pressure sensor of Freon (Vy2).
B1233 The temperature sensor of Freon (Vy2/y). It is not always completed.
B1234 Sun sensor (Ve2).
B1235 The sensor of harmful substances in air (Vey).
B1241 The level of Freon (temperature + pressure).
B1416 The circulating pump of the additional circulation of tosola (M13).
B1417 The dual valve of tosola of left side (Y21).
B1418 The dual valve of tosola of right side (Y21).
B1419 Electromagnetic coupling of compressor (A9k1).
B1420 The system of an increase in the idling speed.
B1421 Clock module (N65).
B1422 Sequential interface (Ky) of the combination of instruments (Ay).
B1423 Planck valves (Y11) of the managers air dampers.
B1424 The engine of filter with the activated carbon (A32m2).OTKR.
B1425 the engine of filter with the activated carbon (A32m2). IT WILL CLOSE.
B1432 Additional heater.
B1459 Sequential interface (K2) of the combination of instruments (Ay).
B1462 The signal of the full load of engine



cia va vaizdziau

http://www.youtube.com/watch?v=4h-XK...eature=related


Paskutinį kartą redagavo Edgaras; 2009-09-30 19:46 val.
nissen29 neprisijungęs   Cituoti